Kami gunakan kuki dan teknologi yang lain pada laman web ini untuk menambah baik pengalaman anda.
Dengan klik mana-mana pautan pada halaman ini, anda bersetuju dengan Dasar Privasi dan Dasar Kuki kami.
Ok Saya Setuju Baca Yang Selanjutnya

Mengenai Pipe Headloss Calculator Plus

Untuk menganggarkan kerugian kepala air dalam paip

Pipe Headloss Calculator Plus app can be used for estimating frictional head loss in pipes. This app version compared to the free includes fittings and valves calculation and selection of the pipe material.

The total pressure loss in the system results from the combined losses due to friction in length of pipe and friction losses due to valves, fittings, and other components. The first are "major losses" associated with energy loss per length of pipe, and seconds are "minor losses" associated with bends, fittings, valves, etc.

The factors that determine friction losses in pipe are:

The velocity of the water: As velocity increases, pressure losses increase. Velocity is directly related to flow rate.

The size (inside diameter) of the pipe: Smaller pipe causes a greater proportion of the water to be in contact with the pipe, which creates friction. Pipe size also affects velocity. Given a constant flow rate, decreasing pipe size increases the water’s velocity, which increases friction.

The roughness of the inside of the pipe: Pipe inside wall roughness is rated by a C factor, which can be selected depending on material of pipe. The lower the C value, the rougher the inside and the more pressure loss due to friction.

The length of the pipe: The friction losses are cumulative as the water travels through the length of pipe. The greater the distance, the greater the friction losses will be.

The friction losses for, elbows, and tees can also be selected. The friction losses in fittings such as couplings, elbows, tees, valves and other elements play a role. Friction loss from these components must be taken into account when calculating friction losses for each section of pipe.

Calculation of friction factor is based on the Hazen-Williams equation. Local resistances factor K for valves and some fittings (tees, elbows, pipes contraction and enlargement), can be found in app itself.

Example:

Calculate pressure losses in a pumping of 10 l / s. The diameter of the suction and discharge is 100 mm or 4 ". We have the following items on the Suction: 1 foot valve, 1 gate valve , 1 elbow 90, 1 contraction to 3" to entering the pump. In the discharge we have: 1 expansion, 2 elbow 90,

a check valve, 1 gate valve. The total pipe length is 10 meters in diameter of 100 mm. Must be calculated the pressure losses for the given flow.

Apa yang baru dalam versi terkini 1.5.2

Last updated on Aug 13, 2013

Minor bug fixes and improvements. Install or update to the newest version to check it out!

Terjemahan Memuatkan...

Maklumat APLIKASI tambahan

Versi Terbaru

Minta Pipe Headloss Calculator Plus Kemas kini 1.5.2

Memerlukan Android

1.6

Tunjukkan Lagi

Pipe Headloss Calculator Plus Tangkapan skrin

Langgan APKPure
Jadilah yang pertama untuk mendapatkan akses kepada pelepasan awal, berita, dan panduan permainan dan aplikasi Android terbaik.
Tidak, Terima kasih
Daftar
Berjaya berjaya!
Anda kini melanggan APKPure.
Langgan APKPure
Jadilah yang pertama untuk mendapatkan akses kepada pelepasan awal, berita, dan panduan permainan dan aplikasi Android terbaik.
Tidak, Terima kasih
Daftar
Kejayaan!
Anda kini melanggan surat berita kami.