We use cookies and other technologies on this website to enhance your user experience.
By clicking any link on this page you are giving your consent to our Privacy Policy and Cookies Policy.

Informazioni su Transformer Spray design

Standard per Acqua Spray impianti fissi per la protezione antincendio.

The Standard for Water Spray Fixed Systems for Fire Protection, formerly Water Spray Nozzles and

Extinguishing Systems, first prepared by the Committee on Manufacturing Hazards, was tentatively adopted in 1939, with final adoption in 1940. Subsequently, this standard was placed under the jurisdiction of the Committee on Special Extinguishing Systems, and a new edition was adopted in 1947. In 1959, the committee organization was further changed to place primary responsibility in the hands of the Committee on Water Spray, under the general supervision of the General Committee on Special Extinguishing Methods. In 1966, the General Committee on Special Extinguishing Methods was discontinued, and the Committee on

Water Spray was constituted as an independent committee. Revised editions were presented

in 1969, 1973, 1977, 1979, and 1982

.

Download Manule Link:

https://drive.google.com/file/d/0BxaWWGlfYY6NQUk1SGE1UkwtWnM/view?usp=sharing

1.1.1 This standard provides the minimum requirements for the design, installation, and system acceptance testing of water spray fixed systems for fire protection service and the minimum requirements for the periodic testing and maintenance of ultra-high-speed water spray fixed systems.

1.1.2* Water spray fixed systems shall be specifically designed to provide for effective fire control, extinguishment, prevention, or exposure protection.

1.1.3* This standard shall not apply to water spray protection

from portable nozzles, sprinkler systems, monitor nozzles, water

mist suppression systems, explosion suppression, or other means

of application covered by other standards of NFPA.

1.2 Purpose. The purpose of this standard shall be to provide

the minimum requirements for water spray fixed systems based

on sound engineering principles, test data, and field experience.

1.3 Application.

1.3.1 Water spray is applicable for protection of specific hazards

and equipment and shall be permitted to be installed independently of, or supplementary to, other forms of fire protection

systems or equipment.

1.3.2 Water spray protection is acceptable for the protection

of hazards involving each of the following groups:

(1) Gaseous and liquid flammable materials

(2) Electrical hazards such as transformers, oil switches, motors, cable trays, and cable runs

(3) Ordinary combustibles such as paper, wood, and textiles

(4) Certain hazardous solids such as propellants and pyrotechnics

(5) Vapor mitigation

1.4 Retroactivity. The provisions of this standard reflect a consensus of what is necessary to provide an acceptable degree of

protection from the hazards addressed in this standard at the

time the standard was issued.

1.4.1 Unless otherwise specified, the provisions of this standard shall not apply to facilities, equipment, structures, or installations that existed or were approved for construction or

installation prior to the effective date of the standard. Where

specified, the provisions of this standard shall be retroactive.

1.4.2 The retroactive requirements of this standard shall be permitted to be modified if their application clearly would be impractical in the judgment of the authority having jurisdiction, and only where it is clearly evident that a reasonable degree of safety is provided.

1.5 Equivalency. Nothing in this standard is intended to prevent the use of systems, methods, or devices of equivalent or superior quality, strength, fire resistance, effectiveness, durability, and safety over those prescribed by this standard. Technical documentation shall be submitted to the authority having jurisdiction to demonstrate equivalency. The system, method, or device shall be approved for the intended purpose by the authority having jurisdiction.

Function

1. Method Design

2. Number Sprinkler Design

3. Area Calculate

4. Flow Sprinkler Calculate

5. Pressure & Flow Sprinkler Calvulate

6. Frictional Loss Calculate

7. Table For Design

8. Graph For Design

Novità nell'ultima versione 1.0

Last updated on Dec 18, 2015

Minor bug fixes and improvements. Install or update to the newest version to check it out!

Traduzione in caricamento...

Informazioni APP aggiuntive

Ultima versione

Richiedi aggiornamento Transformer Spray design 1.0

È necessario Android

2.2

Mostra Altro

Transformer Spray design Screenshot

Iscriviti ad APKPure
Sii il primo ad accedere alla versione anticipata, alle notizie e alle guide dei migliori giochi e app Android.
No grazie
Iscrizione
Abbonato con successo!
Ora sei iscritto ad APKPure.
Iscriviti ad APKPure
Sii il primo ad accedere alla versione anticipata, alle notizie e alle guide dei migliori giochi e app Android.
No grazie
Iscrizione
Successo!
Ora sei iscritto alla nostra newsletter.